Davenport
Trusted HVAC Specialists in Davenport, FL
For reliable heating and cooling services in Davenport, FL, you can count on us at Underwood AC to deliver long lasting results. We provide a full range of AC and heating solutions, plus air quality services, water heater services, and pool heating installation. The next time you notice any signs of trouble with your HVAC system, just reach out to us and we’ll take care of everything.

Complete HVAC and Air Quality Services in Davenport
We provide a wide range of services throughout Polk County that include:
AC Repair, Installation & Maintenance
Stay cool when it matters most with our complete air conditioning services, including repairs, new installations, and routine maintenance.
Furnace Repair & Installation
A well-maintained furnace is essential in colder months. We provide repairs, installations, and maintenance to ensure reliable warmth.
Ductless AC Options
Ductless air conditioning is an excellent choice if your home lacks ductwork. We offer installation and repair for energy-efficient cooling.
Professional Air Handler Services
Struggling with weak airflow? Our air handler services will restore proper circulation, improving comfort throughout your home.
Heat Pump Installation & Repairs
Since heat pumps work year-round, they need regular care. We provide expert repair and installation to keep yours running efficiently.
UV Air Sanitizer Installation
Eliminate airborne bacteria and allergens with our UV air sanitizers, designed to improve the air quality in your living space.
Dehumidifier Replacement & Installation
Too much humidity can lead to mold and discomfort. Our dehumidifier services help you maintain the perfect indoor moisture levels.
Indoor Air Quality Testing
If you’re concerned about indoor pollutants, our air quality testing will identify problems and help you breathe easier.
Ductwork Installation
Damaged or outdated ducts can impact your HVAC system’s efficiency. Our expert installation services keep air distribution optimal.
Air Purification & Filtration Services
Minimize airborne contaminants with our air filtration systems, which help maintain a healthier home environment.
Water Heater Repairs & New Installations
From unexpected breakdowns to upgrading your system, we offer water heater repairs and installations for consistent hot water.
Gas & Electric Pool Heater Installation
Make every season swim season with our professional gas and electric pool heater installations, designed for year-round comfort.
Preventative HVAC Maintenance Plans
Regular maintenance helps your HVAC system last longer. Our service agreements keep it running smoothly with scheduled tune-ups.
Get in touch with us today if you’d like to learn more about any of our services, or if you’re ready to schedule an appointment.
Affordable HVAC Financing Options
There’s no need to delay necessary repairs or system upgrades because we offer three financing plans to keep your home comfortable without the financial stress.
Why Choose Us?
Your HVAC system deserves expert attention, and we’re here to provide just that. Our experienced team is dedicated to delivering high-quality service while giving you a smooth, hassle-free experience from start to finish. We value long-term relationships and are committed to exceeding your expectations. Here’s what you can count on when you work with us:
Frequently Asked Questions
Below, you’ll find some frequently asked questions about our range of services in Davenport.
Regular maintenance is key to keeping your AC running efficiently. We recommend scheduling a professional inspection at least once per year to catch potential issues early. This helps your system operate at peak performance, reduces energy consumption, and extends the unit’s lifespan.
Ductless air conditioning provides a flexible cooling solution, especially for homes without existing ductwork. These systems allow for customized temperature control in different rooms, improving energy efficiency and comfort. Their sleek design and quiet operation make them a popular alternative to traditional HVAC systems.
Maintaining good indoor air quality involves several steps. Keeping your HVAC system clean and replacing filters regularly can help reduce dust and allergens. Installing air purifiers or using UV air sanitizers can further eliminate airborne contaminants, creating a fresher and healthier environment.
Choosing the right furnace involves selecting a unit that matches your home’s heating needs. A properly sized and energy-efficient system will provide reliable warmth while keeping utility costs in check. Professional installation ensures safe operation and compliance with local building codes.
If you experience weak airflow, temperature inconsistencies, or a sudden rise in energy bills, your ductwork might be the culprit. Damaged or outdated ducts can allow air leaks, making your HVAC system work harder than necessary. A professional assessment can determine if repairs or a full replacement would improve efficiency and indoor comfort.
A pool heater lets you enjoy swimming in comfortable water temperatures year-round. It extends your pool’s usability beyond summer, allowing for more relaxation and entertainment options. With gas and electric models available, you can select an option that best suits your home’s energy needs and budget.
Excess moisture in the air can make your home feel damp, encourage mold growth, and create an uncomfortable living environment. A dehumidifier removes excess humidity, helping to maintain balanced indoor air conditions. This not only enhances comfort but also protects your home from moisture-related damage.
If your home has poor airflow, strange noises coming from your system, or uneven cooling and heating, your air handler might need attention. An inefficient air handler can reduce your HVAC system’s overall performance and increase energy costs. Professional repair or replacement can restore airflow and improve home comfort.
Indoor air quality testing helps identify harmful pollutants like dust, mold, and allergens that could be affecting your health. Poor air quality can lead to allergy symptoms, respiratory issues, and general discomfort. A professional assessment can determine the best solutions to improve your home’s air, such as advanced filtration systems or better ventilation.
Contact Form
We’re Here to Help. Contact Us Today!

Contact Us
Take the Next Step
At Underwood AC, we provide expert AC repair and maintenance in Davenport, FL, that will keep your air conditioner running at full capacity. Schedule an appointment with us today so we can get started.
Recent Jobs and Reviews in Davenport, FL
Davenport, FL at a glance
Underwood AC has completed 10 jobs in Davenport, FL between October 2026 and November 2026.
The 10 customer reviews shown here average 5.0 out of 5.
The most recent job was on November 5, 2026.
Underwood AC has completed 203 jobs in Davenport, FL in the last 12 months. The first job there was in April 2025.
Job Locations and Reviews
Upon arrival, I found the evaporator coil frozen. I returned to check the system pressures and verify proper operation. I turned the system on in cooling mode and monitored its performance. The system was operating and cooling properly at the time of inspection. The following readings were recorded: * Suction pressure: 120 PSI * Liquid pressure: 309.5 PSI * Superheat: 15°F * Subcooling: 11°F * Return air temperature: 75.7°F * Supply air temperature: 57°F * Temperature split: 18.7°F Based on these readings, the system is currently cooling within an acceptable range. Additional Findings and Recommendations: There is a high possibility that the previously identified maintenance and repair issues are contributing to the evaporator coil freezing up. The following work is recommended: 1. Remove the evaporator coil for a thorough cleaning. 2. Clean the blower wheel, which is heavily affected by debris. 3. Replace the pitted contactor. 4. Replace the capacitor. 5. Perform microbial sanit
Performed a diagnostic on a 4-year-old Goodman 3-ton straight-cool system with electric heat. I checked system operation in both cooling and heating modes. The system is currently operating in both modes. I checked compressor amperage, condenser fan motor amperage, blower motor amperage, electric heater amperage, refrigerant pressures, subcooling, superheat, and temperature split. During the inspection, I found the following issues: * Condenser coil is dirty. * Contactor is pitted. * Evaporator coil is dirty. * Debris buildup on the blower wheel. * Bacterial growth present on the evaporator coil and inside the air handler cabinet. * Drain pan is dirty. * Supply plenum has air leakage. Although the system is currently operational, it is not operating efficiently and is outside manufacturer specifications at this time. I prepared an estimate for the recommended repairs and cleaning services and presented it to the customer. The customer decided to keep the system as it is for now due
Performed a leak search on the newly installed Daikin system and found a refrigerant leak at the factory brazed connection on the liquid line. I documented the leak with a video showing bubbles during the leak detection process. I repaired the leaking connection by re-brazing it while flowing nitrogen through the line to prevent oxidation. After completing the repair, I pressure-tested the system and performed a vacuum, pulling down to 375 microns. I then released the refrigerant and added 6 pounds of R-32 refrigerant. After completing the repair and charging the system, I checked its operation. The unit is cooling and draining properly at this time.
Performed a diagnostic on the downstairs Goodman unit, approximately 9 years old. Found the system drain line clogged, causing the safety float switch to fill with water and interrupt the thermostat voltage as a safety precaution. Contacted Paul and received approval to perform the drain cleaning. Cleared the drain line and flushed it with approximately 6 gallons of hot water until the water ran clear. Cleaned the drain pan and applied Viper treatment. After completing the drain cleaning, I tested the system operation and confirmed the unit returned to cooling mode. I also inspected the electrical components. The capacitor was within manufacturer specifications; however, the condenser contactor was badly pitted. Contacted Paul again and received approval for contactor replacement. Replaced the contactor and tested the system again. The system is cooling and draining properly, and all components are operating normally at this time.
Performed a diagnostic due to the drain line overflowing and activating the safety float switch. The customer showed me water trapped inside the return duct. The system also has another drain trap installed underneath the slab with a vent pipe. The customer reported attempting to clear the drain line multiple times, but the issue continued. I ran a drain snake through the line from outside to inside and from inside to outside. I found debris and significant algae buildup inside the drain line. When testing drainage directly from the drain pan, I noticed that the water was still overflowing. I then cut the drain line near the drain pan and identified a blockage. I cleared the blockage, cleaned the drain line, and reconnected the piping using PVC glue. I flushed approximately three gallons of hot water through the drain line until the water ran clear. A significant amount of algae and debris was removed. I also cleaned the drain pan and applied Viper drain treatment. After completing
Recovered the refrigerant from the condensing coil. Flowed nitrogen through the refrigerant lines during the installation process. Installed a new Teflon gasket and completed brazing with nitrogen flowing through the lines to prevent oxidation. Performed a pressure test at 350 PSI to verify system integrity. Once the pressure test was completed, evacuated the system to 360 microns. Released the refrigerant back into the system and added 5 pounds of R-410A. Started and tested the system operation. The unit is cooling properly and the condensate drain is draining properly at this time.
Performed preventive maintenance on the pool heater heat pump. Checked system operating pressures, contactor, capacitor, and temperature split between the pool water and evaporator coil. Verified that the capacitor is operating within the manufacturer’s specifications. Inspected and rinsed the condenser coil to remove accumulated debris. Tested overall system operation and confirmed that the pool heater is operating properly at this time.
Performed preventive maintenance under the maintenance contract on the gas furnace. Tested system operation in heating mode and found the furnace operating properly. However, I noticed the unit is equipped with a two-stage gas furnace, but only the low stage is currently connected and operating. The W2 wire is not connected, preventing the furnace from operating in high-stage heating and reaching its full heating capacity. I brought this issue to the customer’s attention and explained the importance of connecting the W2 wiring and programming the thermostat for two-stage operation. I offered to have the wiring connected and the thermostat properly programmed, but the customer declined the recommendation at this time. I also tested the system in cooling mode and confirmed proper operation. Checked compressor amperage, condenser fan motor amperage, and indoor blower motor amperage. Capacitor readings are within manufacturer specifications, and the contactor is in good condition. Addit
extremely knowledgeable, and provides outstanding customer service. I would highly recommend Victor/Underwood to anyone in need of AC service.
Performed a system diagnostic and found the condensate drain line extremely clogged. I cleared the blockage by running a drain snake from inside to outside and outside to inside. I then applied Drain Solve and allowed it to sit for 15 minutes to break down the buildup. Afterward, I flushed the drain line until the water ran clear. The drain pan was clean; I brushed it and applied Viper drain treatment. I also flushed the drain line with approximately 6–8 gallons of hot water. Finally, I tested the condensate drainage and confirmed proper water flow. The system is draining properly and cooling at this time.
Great job explaining the issue and how to resolve the problem at hand.
Performed a diagnostic on a 23-year-old Thermo-Start heat pump system. The unit was calling for cooling but operating in heating mode. I checked the reversing valve wiring from the thermostat to the outdoor unit and confirmed that the reversing valve signal was energized. However, when checking the output from the defrost control board to the reversing valve solenoid, I measured only 3.2 volts instead of the required 24 volts. While inspecting and manipulating the board terminals, I noticed that the system switched back to cooling mode. This indicates an intermittent issue with the defrost control board, potentially caused by a loose terminal, damaged terminal connection or mounting support, or a faulty board relay. The control board is not field-repairable, and replacement of the defrost control board is required to address the issue. I explained to the homeowner that the replacement board may still be available but would likely need to be special-ordered due to the age of the equi
Excellent.
AC was not turning on. Alex fixed the problem and showed me how to maintain the drain line as well.
Very professional and efficient. Was straightforward and helpful, and very clear in describing the situation and prices.
Been using them since I moved in to this house three years ago and always great experience.
We had a great experience with Victor. He was extremely knowledgeable and professional throughout the entire visit. He was also very patient and took time to explain everything that was wrong with the unit in a way that was easy to understand. I truly appreciate his honesty, expertise and attention to detail. Excellent service. I would highly recommend him!
Victor was amazing! Very knowledgeable and explained in detail steps he was taking to conduct maintenance and UV protection! Customer was above and beyond excellence!
HVAC drain was stopped with debris. Checked inside and out unit.
N/A
Contact Form
We’re Here to Help. Contact Us Today!

Get Started Today
Are you looking for proven heating and cooling services in Davenport, FL? At Underwood AC, we take our role in the community seriously, and we are always ready to provide you with the service you need. Book an appointment today to get started.


